The new sterilization system
A NEW WAY OF INTERPRETING THE AUTOCLAVE

BIG LOAD
New regulations and a renewed culture of prevention have developed sterilization practices that are now systematically applied in all medical and dental facilities.
This situation, combined with the wide variety of instruments used, as well as the emergence of multi-professional structures, have given rise to the need for autoclaves that allow the sterilization of increasingly larger loads.
The Onyx project was born precisely with the aim of satisfying these needs, adopting specific and innovative solutions that allow even partial loads to be easily managed.
UNIQUE AND INDISPENSABLE DEVICE
The autoclave is a crucial product in the organization of medical practice within any facility, therefore it is essential to be able to choose a well-known, referenced, and widespread product, which can count on a widespread technical support network.
Onyx B is the new autoclave from Tecno-Gaz, a company that has been a leader in many European and world markets for years.
CYCLES FOR EVERY NEED
Flexibility is essential to streamline work and create operational efficiency.
Onyx B has a wide choice of cycles designed to help you in your daily work.
TRACEABILITY AND IDENTIFICATION
ONYX B contains operator identification systems, cycle validation and alphanumeric label printing and production systems in its technological heart.

DOUBLE LOAD… SAME TIME
With a standard-sized autoclave, you can sterilize an average of 4 kg; with Onyx B, you can sterilize a full 7.5 kg of instruments. A single double-load cycle reduces sterilization time by 50%.
BETTER INSTRUMENT MANAGEMENT
Having a large-capacity autoclave helps streamline instrument flow and increases your operational efficiency.
Efficiency equals profit, Onyx B helps you with this too.
ENERGY SAVING
Onyx B has low energy consumption and an unbeatable consumption/load ratio.
Economic savings and benefits for the environment.
LONGER TRAYS (+30%)
The large trays allow you to insert instruments with bulky bags, arrange the load more rationally, thus being able to carry large loads and following the correct instructions for load arrangement.
SD CARD
The SD card system ensures the recording and archiving of data from all cycles performed, which can then be downloaded to a PC and managed.
The SD CARD system allows you to constantly update the equipment, simply by downloading the updates to it electronically and then inserting it into the autoclave system.
An extraordinary option to always have your device efficient and up-to-date.
PID SYSTEM
PID stands for proportional integral derivative and is the ultimate expression of closed-loop control.
The structure of this sophisticated control is simple and flexible. PID ensures constant control and monitoring of the entire autoclave functional system, automatically intervening in the event of anomalies in the incorrect technical and electronic parameters.
A device that behaves like “a real technician” with real-time diagnosis and intervention capabilities.
A solution that limits anomalies, alarms, and potential machine downtime, ensuring maximum reliability.
FL SYSTEM - FULL LOAD
To avoid manual loads, with the possibility of external water transfer, Onyx B has an automatic pure water tank system, via a sensor-controlled pump with “overflow” level and automatic block.
The loading is frontal, it has no opening or removable cover system, thus allowing for simple recessing of the appliance.
PHD SYSTEM
PRE-HEATING DEVICE
Preheating system with stand-by, to maintain the minimum temperature and consequently reduce the overall times of the sterilization cycles.
INSPECTABLE TANKS
In the event of the insertion of unsuitable liquids, the autoclave tanks can be inspected and cleaned, as required by technical regulations.
Onyx B is equipped with tanks for pure water and used water.
Each tank is equipped with probes to indicate the levels.
NIGHT CYCLES
Automatic night cycles with anti-condensation system and automatic switch-off.
7 STERILIZATION CYCLES
Onyx B was created with the aim of rationalising the work of sterilisation operators, therefore the decision was made to equip this equipment with a series of cycles, designed to best manage time and operational needs, in an outpatient setting.
FULLY AUTOMATIC CYCLES
All cycles are completely automatic, all phases are managed by the advanced board complete with a sophisticated microprocessor.
Each phase (vacuum, preheating, exposure time, drying) is monitored, supported and managed automatically.
There is no human involvement in the unfolding of the cycles.

LOAD TRACEABILITY MANAGEMENT
A very important procedure for the legal protection it plays is the traceability of sterilized loads.
This procedure, aimed at monitoring the progress of the instruments, requires the marking of the load present in the sterilization bags, through the application of a label which must include the batch, sterilization date and other cycle data.
Onyx B helps you fulfill this function thanks to its integrated software that allows you to print labels with data and bar codes. All you need is a dedicated printer (optional item 2110S) and a bar code reader (optional item 3ELNL0001) to implement the entire computerized traceability phase.
A fast, economical, and advanced system that allows you to manage a high-value legal procedure simply and rationally.
ID SYSTEM
Integrated password-protected operator authentication system that allows the operator to be associated with the sterilized load at the end of the cycle and also has visual validation of the operator himself.
This authentication is then also reported in the load tracking procedure.
PURA PLUS
The autoclave is water-independent as it is equipped with a double tank for pure water and waste water, and is designed for connection to the water mains via the PURA Plus osmosis system (Optional).