Masterflux Smart.
The first. In the world.
The first electronic conscious sedation system 4.0
Tecno Gaz spa, a leader in sedation for over 30 years, has developed MasterFlux Smart, the first electronic conscious sedation system with advanced IoT connectivity 100% Made in Tecno-Gaz.




Ease of use
POSSIBILITY TO CONSULT USAGE VALUES, USB EXPORT
Work in complete safety
MECHANICAL-PNEUMATIC SAFETY DEVICES AND ELECTRONIC CONTROL OF DELIVERY PARAMETERS

User and patient profiling
PATIENT DATA, BASELINE RECORDING. MEDICAL USE DATA.
Simple and intuitive,
just a touch away!
Simple and accessible menus, designed for maximum operability. The high level of customization makes the TYGI 400evo control system extremely flexible and capable of adapting to the operator's working style or workflow evolutions.

Delivery parameters
DISPLAY OF ELECTRONICALLY REGULATED PARAMETERS
Autonomy display
CALCULATION AND DISPLAY FUNCTION OF RESIDUAL CYLINDER AUTONOMY IN MINUTES

Management of exhaled gases
OPTIMIZATION OF THE INTAKE-EXHAUST FLOW OF EXHALED GASES (ADJUSTABLE)
The first device
for IOT sedation
Wi-Fi connected. Unique in the world.

MasterFlux SMART is a sophisticated electronic and mechanical engineering project with a proportioning dispensing system. The electronic method allows for precise flow regulation simply by turning a proportioning knob. This high-precision, highly reliable, and easy-to-use product is cloud-connected for data management (IoT).

You can choose to connect it to the cloud for management and consultation of patient flow data on Tecno-Gaz servers, or alternatively use it independently in offline mode.

Real-time control

Data backup and statistics

Accessible everywhere
The 5 advantages of the Intelflix system
The Intelliflux system allows the coupled circuit tubes to be positioned above the patient's head, on the right or left end, allowing the dentist to work with maximum comfort on the area to be treated without having any pipes getting in the way.
Maximum ergonomics
of workPerfectly suited for four-handed work. The circuit junction located above the patient's head does not create obstacles to treatment... suitable for all dental practices with particular attention to surgery .
Pleasant treatment
The sedated patient has a pleasant experience breathing through a mask that leaves no marks on his face. The front support, the elastic band and the locking system on the headrest of the dental unit guarantee perfect stability.
Maximum stability
Extremely stable masks thanks to the rigid polycarbonate central body and the soft silicone profile.
STABILIZES AND AVOIDS DISPERSIONS.
Effective and efficient conscious sedation
The perfect fit of the masks, which adapt to any face shape, allows for faster and more efficient conscious sedation treatment. A rigid polycarbonate central body and a soft silicone profile ensure maximum seal and stability.
No dispersion
in the environmentThe particular construction technique of the Intelliplux masks allows to avoid gas dispersions in the environment:
- Non-return valve
- Adaptive connector for dental unit aspirators
- New "easy breathing" membrane
- Adaptive silicone pad

INTELLIFLUX
Ergonomics
Perfect adaptation to the surface of the face and total reduction of gases exhaled into the environment.
Simplicity
Easy to assemble pipes with anti-kink system.
Comfort
Adaptive silicone profile for all face types, leaves no mark and guarantees great comfort.
Safety
This device prevents the dispersion of gas into the environment.
Hygiene
Autoclavable masks for maximum hygiene.
Practicality
The tubes are long enough not to get in the way when working with four hands.
What can be sterilized?
Safety always comes first
LET'S SEE THE AUTOCLAVABLE PARTS OF THE INTELLIFLUX CIRCUIT
Tecno-Gaz, a European leader in sterilization , publishes best practices for the use of masks to prevent cross-contamination, as recommended by European standards: EN 13060, EN17665-1, EN556-1, Spaulding classification. Spaulding defines the criticality of instruments used during dental treatment (critical, semi-critical, non-critical) based on their use and the possibility of contact with the patient's skin and/or rubber and tissues.
In particular, it is possible to sterilize:
- silicone (latex free) and polycarbonate masks at 134°C
- special autoclavable tubes (on demand) at 121°C or 134°C.
The neck band and disposable tubes, however, must be disposed of after each use.




Silicone masks
4 MASKS SUITABLE FOR EVERY TYPE OF PATIENT
(CHILDREN AND ADULTS)
One-size-fits-all silicone face masks with a nose profile available in various sizes:
- Size 1 - XS
- Size 2 - S
- Size 3 - M
- Size 4 - L
Autoclavable at 134°C. Minimum: 30 cycles.
Structure of the masks
COMFORTABLE AND FUNCTIONAL IN EVERY SITUATION
- Support for the patient's front area.
- Gas outlet with non-return valve.
- Gas inlet with non-return valve.
- Soft and adaptive membranes to facilitate breathing.
- Rigid polycarbonate front body for maximum sealing with zero dispersion and operator safety.

Spare parts and accessories
One-size silicone forehead support and nose profile in various sizes
AUTOCLAVABLE AT 134°C. MINIMUM: 30 CYCLES
- Size 1 - XS Art. No. 2ZMFA0050
- Size 2 - S Art. No. 2ZMFA0051
- Size 3 - M Art. No. 2ZMFA0052
- Size 4 - L Art. No. 2ZMFA0054


Autoclavable circuit tube
AUTOCLAVABLE AT 134°C. MINIMUM: 30 CYCLES
Length 1.5 meters Art. No. 3MEDT0018
Disposable circuit tube
DISPOSABLE TUBE IN ROLL
Length 50 meters with dividers Art. No. 3MEDT0019

Why is Intelflix different from other circuits on the market?
Classical circuit defects
- Difficult access to the oral cavity with the professional's instruments due to the tubes that pass through the cheekbone area.
- The mask leaves a mark on the patient's face .


Non-invasive circuit defects
- Dispersion in the environment and precarious stability due to attack with a sticky substance.
- Rubbery material without rigid central body, does not prevent distortion and loss of seal .
- They are disposable and the cost per treatment is high .